PRODUCT PARAMETERS
- Vertical structure design: The vertical casing offers flexible installation, and a suitable installation position can be selected according to building space and project conditions.
- Jet air supply design: The dedicated air supply structure forms an airflow with certain velocity and reach, expanding the air delivery range.
- Long-distance air supply: Combining the fan with jet air supply components, the unit delivers air over long distances, suitable for large spaces and long-distance air supply needs.
- High-efficiency heat exchange: Equipped with heat exchange coils to achieve indoor air temperature regulation through heat exchange between air and chilled/hot water.
- Optional air filtration device: The filtration device is an optional configuration that can be installed or omitted per project requirements, with different filtration grades available as needed.
- Flexible airflow organization: Air supply direction and airflow coverage can be rationally designed according to building layout and actual air supply needs.
- Stable operation: The fan and heat exchange components work together to achieve continuous air circulation, temperature regulation and long-distance air supply.
- Flexible configurations: Air volume, cooling capacity, external static pressure, jet air supply components, filtration device and control options can be selected per project requirements.
Description
Product features of the vertical unit:
- Rigid base frame for easy transport; large units can be assembled on site.
- Aluminum alloy (aluminum-plastic) frame profiles with 0.4~1 mm double-layer panels, surface coated with anti-corrosion paint; the interlayer is filled with mineral wool or PU foam, with good thermal insulation, ensuring no cold bridge or condensation leakage.
- All components of the unit are strictly tested and can operate normally in any climate.
- An automatic control system can be configured for automated control and energy-saving operation.
- Bottom drainage design (1.5% slope) ensures smooth condensate discharge.
- Can be tailored to user requirements.
The vertical jet air handling unit is a terminal device widely used in central air-conditioning and air treatment systems, mainly for cooling, heating and long-distance air supply of indoor air. With a vertical floor-standing structure and a compact overall layout, the unit can be flexibly installed according to building space and project requirements, and is suitable for large commercial buildings, public venues and other places with requirements on air delivery distance and coverage.
The unit mainly consists of a casing, heat exchange coil, fan, motor and jet air supply components, and the air filtration device can be installed as an option according to project requirements. Driven by the fan, air flows through the heat exchange coil and exchanges heat with chilled/hot water to regulate air temperature, and the treated air is then delivered to distant areas through the jet air supply structure. With the optional filtration device, the air passing through the unit can also be filtered to meet the air quality requirements of different projects.
Combining air treatment with jet air supply technology, the product features long air delivery distance, flexible airflow organization, diverse installation methods and flexible configurations, and is suitable for shopping malls, gymnasiums, exhibition halls, factories and other large-space central air-conditioning projects.
Applications
- Large shopping malls and shopping centers
- Gymnasiums and sports venues
- Exhibition halls and convention centers
- Airports and transportation hubs
- Large conference halls and multi-function halls
- Factories and industrial buildings
- Hotels and large public buildings
- Other large-space central air-conditioning engineering projects
Product Advantages
The vertical jet air handling unit combines air temperature regulation with jet air supply technology, delivering treated air to distant areas while cooling and heating indoor air, expanding air supply coverage and improving air circulation and temperature distribution in large spaces. With the heat exchange coil and fan as main functional components and an optional air filtration device, the filtration device and its grade can be selected according to the air quality requirements of different projects.
With a vertical installation structure, long-distance air supply, flexible airflow organization and diverse configurations, the product meets the air conditioning needs of large commercial buildings, public venues, industrial buildings and other premises. We can provide vertical jet air handling units in different specifications and configurations according to actual customer project requirements, delivering a flexible and reliable air treatment solution for various large-space central air-conditioning projects.
FAQs
We are a manufacturer of ventilation, air-conditioning, dust-removal and smoke-exhaust equipment. Our range covers fire smoke-exhaust fans, fire dampers and smoke-exhaust valves, aluminium air outlets and diffusers, ventilation ductwork and silencers, air-handling and fresh-air units, water tanks, cooling towers, seismic supports, and air-purification and kitchen oil-fume purification equipment.
Yes. Our fire dampers, smoke-exhaust fire dampers, smoke-exhaust valves and fire smoke-exhaust fans carry CCCF (3C) certification. For every fire-protection product we can supply national-level fire test reports together with the complete CCCF documentation package.
The company is certified to ISO 9001 (quality), ISO 14001 (environmental) and ISO 45001 (occupational health and safety) management systems, and holds AAA-grade certificates as a quality-assured, contract-honouring enterprise.
Our fan series includes CCCF axial fire smoke-exhaust fans, CCCF centrifugal fan boxes for fire service, pressurization supply fans, diagonal-flow fans, mixed-flow fans, axial fans, ceiling-mounted and floor-standing fresh-air ventilators, heat-recovery units, and finned-tube, rotary-wheel and heat-pipe air-handling units.
Dampers: CCCF automatic fire dampers, CCCF automatic smoke-exhaust fire dampers, CCCF automatic smoke-exhaust valves, manual balancing dampers, non-return dampers, pressurization supply outlets, multi-blade outlets, and CCCF smoke-exhaust outlets. Aluminium outlets: spherical jet nozzles, swirl diffusers, ceiling diffusers, weatherproof louvers, and single/double-deflection louvers.