Dezhou Deqian HVAC Equipment Co., Ltd.

TS Hot-Water Unit Heater
PRODUCT PARAMETERS
The TS-type hot-water unit heater is a heating device using hot water (50-80 degrees C) as the heating medium. It is an improvement on the GS type, adopting copper-tube radiators with better heat exchange efficiency, suitable for low-temperature 50-80 degree hot water. It can heat indoor air in circulation and is one of the commonly used heating devices in factory buildings of industrial and mining enterprises and in public buildings. Compared with the “GS” type unit heater, it has the following advantages: small size, light weight and low power consumption. This type of unit heater mainly consists of copper tubes, a radiator, a casing, a guard-covered fan, louvers, etc. The radiator has three/four/six/eight rows; the heating medium enters through the pipe connection at the lower part of the first row. Heat is conducted through the tube wall to the fins on the outer surface of the copper tubes and exchanged with the air. The impeller is directly driven by the motor, forcing the air to flow through the fins outside the tube rows, where it gains heat and its temperature rises. The louvers are used to adjust the air direction.
Description
Installation, Use and Maintenance Instructions for the Unit Heater
(1) Check the integrity of the unit heater before installation. (2) The unit heater should be equipped with the corresponding heating-medium piping system; stop valves should be installed on the inlet and return branch pipes of the unit heater, and air venting devices should be provided on the whole piping system. (3) If the air inlet of the unit heater communicates with the outdoor air, a closing device should be provided at the outdoor air inlet, to prevent the heating coil from freezing when the heating-medium supply stops. (4) When the motor is connected to the power supply, the impeller should rotate in the direction indicated by the arrow on the product. (5) The piping system should be cleaned before being connected to the unit heater, and a drain valve should be provided under each unit heater. (6) To facilitate regulation of the water flow of each unit heater in the system, a reversed-return system design is preferred. (7) Before operation, the air in the piping and the heating tubes must be completely vented. (8) The hot water temperature of the unit heater should be kept above 70 degrees C and in no case below 55 degrees C; the flowing water volume must keep the water velocity in the heating coil above 0.2 m/s. (9) Adjust the louver opening angle to obtain suitable airflow. (10) For ease of management, an electric contact thermometer and relay can be installed on the main inlet pipe of the heating-medium system to centrally control the on/off of the unit heaters and prevent the unit heaters from blowing cold air. (11) The unit heater should be flushed regularly with compressed air and water; after 2-3 years of operation, chemical methods should be used to remove the scale in the tube rows. (12) The hot water should be softened, and the piping system should be kept full of water to reduce corrosion.
FAQs
We are a manufacturer of ventilation, air-conditioning, dust-removal and smoke-exhaust equipment. Our range covers fire smoke-exhaust fans, fire dampers and smoke-exhaust valves, aluminium air outlets and diffusers, ventilation ductwork and silencers, air-handling and fresh-air units, water tanks, cooling towers, seismic supports, and air-purification and kitchen oil-fume purification equipment.
Yes. Our fire dampers, smoke-exhaust fire dampers, smoke-exhaust valves and fire smoke-exhaust fans carry CCCF (3C) certification. For every fire-protection product we can supply national-level fire test reports together with the complete CCCF documentation package.
The company is certified to ISO 9001 (quality), ISO 14001 (environmental) and ISO 45001 (occupational health and safety) management systems, and holds AAA-grade certificates as a quality-assured, contract-honouring enterprise.
Our fan series includes CCCF axial fire smoke-exhaust fans, CCCF centrifugal fan boxes for fire service, pressurization supply fans, diagonal-flow fans, mixed-flow fans, axial fans, ceiling-mounted and floor-standing fresh-air ventilators, heat-recovery units, and finned-tube, rotary-wheel and heat-pipe air-handling units.
Dampers: CCCF automatic fire dampers, CCCF automatic smoke-exhaust fire dampers, CCCF automatic smoke-exhaust valves, manual balancing dampers, non-return dampers, pressurization supply outlets, multi-blade outlets, and CCCF smoke-exhaust outlets. Aluminium outlets: spherical jet nozzles, swirl diffusers, ceiling diffusers, weatherproof louvers, and single/double-deflection louvers.