Contact Form

Ceiling Circulating Heating Unit

PRODUCT PARAMETERS

1. Repeated air circulation reduces the temperature gradient.
2. No draft sensation, higher comfort.
3. Both centralized control and individual control are available, simple and convenient to operate.
4. Various operating modes can be easily switched according to indoor conditions.
5. Installed on the ceiling, it maximizes the working space and does not obstruct any internal facilities such as machinery or lighting in the workshop.
6. No supply or return air ducts are required.

Description
FAQs
Request A Quote

Description

Equipment Parameter Table

ModelDHF-D/R-5DHF-D/R-6DHF-D/R-8DHF-D/R-I
Rated Air Flow(m³/h)55006900870011000
Power Supply380V 50Hz
Axial Fan Power(KW)0.420.851.11.85
Centrifugal Fan Power(KW)0.71.51.52.5
Inlet & Outlet Pipe SizeDN32DN32DN40DN50
Installation Height(m)4~84~95~155~17
Min. Distance to Ceiling(mm)250250250250
Max. Distance to Wall(m)9111415
Max. Distance Between Units(m)18222830
Overall Dimension
(L(A)*W(A)*H(B) mm)
800*800*10551100*1100*1130
Weight(kg)137141192196
Control ModeWireless Central Control or Wired Control

★Note: The above product parameters refer to (p27-p29). For non-standard customized products, please consult the salesperson for details.

Main Equipment Components

No.Name
1Primary Filter
2Water Outlet
3Heat Exchanger
4Water Inlet
5Axial Fan
6Actuator
7Air Outlet

FAQs

We are a manufacturer of ventilation, air-conditioning, dust-removal and smoke-exhaust equipment. Our range covers fire smoke-exhaust fans, fire dampers and smoke-exhaust valves, aluminium air outlets and diffusers, ventilation ductwork and silencers, air-handling and fresh-air units, water tanks, cooling towers, seismic supports, and air-purification and kitchen oil-fume purification equipment.

Yes. Our fire dampers, smoke-exhaust fire dampers, smoke-exhaust valves and fire smoke-exhaust fans carry CCCF (3C) certification. For every fire-protection product we can supply national-level fire test reports together with the complete CCCF documentation package.

The company is certified to ISO 9001 (quality), ISO 14001 (environmental) and ISO 45001 (occupational health and safety) management systems, and holds AAA-grade certificates as a quality-assured, contract-honouring enterprise.

Our fan series includes CCCF axial fire smoke-exhaust fans, CCCF centrifugal fan boxes for fire service, pressurization supply fans, diagonal-flow fans, mixed-flow fans, axial fans, ceiling-mounted and floor-standing fresh-air ventilators, heat-recovery units, and finned-tube, rotary-wheel and heat-pipe air-handling units.

Dampers: CCCF automatic fire dampers, CCCF automatic smoke-exhaust fire dampers, CCCF automatic smoke-exhaust valves, manual balancing dampers, non-return dampers, pressurization supply outlets, multi-blade outlets, and CCCF smoke-exhaust outlets. Aluminium outlets: spherical jet nozzles, swirl diffusers, ceiling diffusers, weatherproof louvers, and single/double-deflection louvers.

REQUEST A QUOTE

REQUEST A QUOTE